Bray valves, actuators and controls for industrial buyers
20 November 2026 · Bray

Valve Certifications Explained: API 607, NSF/ANSI 61, SIL, ATEX, PED and NACE

Six certificates cover most valve tenders, and they answer six completely different questions. What each one actually proves, what it does not prove, and the five misreadings that cost projects money.

Certificates are not a quality score

A tender document often lists certifications as if they were a ranking: more certificates, better valve. They are not. Each standard answers a specific question about a specific failure mode, and a valve can hold six certificates and still be wrong for the duty.

The useful question is not "what do you have" but "which certificate covers the failure this line cannot tolerate".

The six that cover most enquiries

Standard The question it answers Typical application
API 607 / API 6FA After a fire and a subsequent pressure test, does the valve still seal? Fire-safe isolation, hydrocarbon, offshore, refineries
API 598 / EN 12266-1 Does the valve pass the shell and seat pressure test, and at which leakage rate? Every project — this is the baseline test standard
NSF/ANSI 61 & 372 Are the wetted materials safe for drinking water, and is lead below the legal limit? Potable water, municipal distribution, food-grade water
IEC 61508 SIL (SC 1–3) What is the systematic capability of the design for safety instrumented functions? SIS loops, ESD valves, safety shutdown
ATEX 2014/34/EU Is the equipment safe to install in a classified explosive atmosphere, and in which zone? Gas and dust hazardous areas, petrochemical
PED 2014/68/EU Does the pressure vessel / pressure equipment meet the EU directive, and at which category? Any CE-marked equipment sold into the EU
NACE MR0175 / ISO 15156 Are the metallic materials acceptable for wet H2S service? Sour gas, oil and gas production, refineries

Three more appear in specific industries: ISO 5211 for the actuator mounting interface, ISO 15848 / TA-Luft for fugitive emissions from the stem seal, and ISO 28921 for cryogenic isolation valves.

The five misreadings that cost money

1. "SIL 3 valve" does not mean a SIL 3 loop. IEC 61508 gives the device a systematic capability (SC) and a failure rate. Whether the loop reaches SIL 3 depends on redundancy, proof-test interval and the logic solver — that is IEC 61511 work, not a valve certificate. A supplier claiming "our valve gives you SIL 3" is answering a question you did not ask.

2. API 607 is per product, not per brand. Fire testing is done on a specific size, pressure class and seat material. A certificate for a DN100 Class 150 with one seat compound does not automatically cover DN600 with another. Always ask for the certificate's scope table and check the size and material you are buying appear in it.

3. NSF/ANSI 61 covers materials, not performance. It confirms the wetted materials do not leach harmful amounts into drinking water. It says nothing about whether the valve will hold 16 bar for twenty years. 372 is separate and specifically about lead content. NSF/ANSI 61 compliant valves

4. ATEX certifies equipment, not an installation. Zone classification, the ignition risk assessment of the process and the earthing of the pipe remain the plant's responsibility. A valve marked for Zone 1 does not make the surrounding system compliant.

5. PED category is a calculation, not a marketing level. Category is derived from pressure, volume or nominal size and the medium group. A larger valve in the same series can move into a higher category and require a notified body. If a supplier quotes "PED certified" without stating the category and the notified body number, the document is not usable in a technical file.

What to actually request in a tender

  1. Certificate scope table — not the certificate cover page. It should list sizes, pressure classes, seat materials and temperature range.
  2. Test report, not just a compliance statement, for API 598 and API 607.
  3. Declaration of Conformity with the PED category and notified body number, if CE marking applies.
  4. Material certificates to EN 10204 3.1 for wetted pressure-retaining parts, if the project requires traceability.
  5. Validity — certificates are revised. Check the issue date and whether the standard edition is current.

Three questions that separate a real certificate from a PDF

Ask which sizes and pressure classes are covered. Ask which seat material was tested. Ask who issued the test and whether the report is available.

A supplier who can answer all three in one reply is holding a real qualification. A supplier who sends a logo and a claim is not.

Download the certification coverage matrix, or send us your tender's certificate clause and we will tell you which scope our product actually covers.