Series 54-HS Inductive Proximity Sensor
The 54 series proximity sensor provides position indication for quarter-turn valves. Its superior design offers reliable, durable valve monitoring and control for efficient plant operation, mounting directly to VDI/VDE.
| Switching Function | Intrinsic Safety - NAMUR = 2 x normally open (NC); DC 2-wire = 2 x normally open (NO) |
|---|---|
| Output Type | Intrinsic Safety = NAMUR; DC 2-wire = 2 x normally open (NO) |
| Communication Protocols | None |
| Rated Operating Distance | Intrinsic Safety - NAMUR = 0 … 2.4mm; DC 2-wire = 0 … 2.05mm |
| Lead time | 7–15 days |
|---|---|
| Minimum order | ≥1 |
Technical Specifications
The 54 series proximity sensor provides position indication for quarter-turn valves. Its superior design offers reliable, durable valve monitoring and control for efficient plant operation, mounting directly to VDI/VDE 3845 compliant actuators for a smaller envelope and cost savings.
Features:
- Two independent sensors indicate open and closed valve positions
- Optimal design for high-pressure flush and corrosive flush applications
- Tightly sealed against ingress of liquids and solids
- Suited to dirty process environments and rapid cycling
- Rugged design resists shock, vibration, UV and corrosion
- Maintenance-free: contactless sensors eliminate mechanical wear and potential switch welding, arcing and sparking
- Fast, simple installation
- LED indication of sensor power, switching and solenoid status
- 2-wire DC output sensor for process environments in hazardous areas
A DC 2-wire sensor for reliable operation in hazardous-area process environments — a compact proximity sensor for precise valve monitoring.
| Switching Function | Intrinsic Safety - NAMUR = 2 x normally open (NC); DC 2-wire = 2 x normally open (NO) |
|---|---|
| Output Type | Intrinsic Safety = NAMUR; DC 2-wire = 2 x normally open (NO) |
| Communication Protocols | None |
| Rated Operating Distance | Intrinsic Safety - NAMUR = 0 … 2.4mm; DC 2-wire = 0 … 2.05mm |
| Enclosure Ratings | Intrinsic Safety = IP67; DC 2-wire = IP66/67/69K |
| Connections | Intrinsic Safety; qty 1: M12 x 1 pin connector; qty 1: M12 x 1 and qty 1: RD24x18 pin connectors; qty 2: M20 x 1.5 cable glands; DC 2-wire |
| Operating Voltage | Intrinsic Safety 8V; DC 2-wire 6 - 30V |
| Mounting | NAMUR/ VDI VDE 3845 |
| Switching Frequency | Intrinsic Safety = 0 ... 3 kHz; DC 2-wire = 0 ... 100 Hz |
| Temperature Range | Intrinsic Safety = -25 ... 100°C (-13 ... 212°F); DC 2-wire = -40 ... 75°C (-40 ... 167°F |
| Certifications | Intrinsic Safety - NAMUR; cULus Listed, General Purpose (E248934); DC 2-wire |
Features & Advantages
- Two independent sensors indicate open and closed valve positions
- Optimal design for high-pressure flush and corrosive flush applications
- Tightly sealed against ingress of liquids and solids
- Suited to dirty process environments and rapid cycling
- Rugged design resists shock, vibration, UV and corrosion
- Maintenance-free: contactless sensors eliminate mechanical wear and potential switch welding, arcing and sparking
- Fast, simple installation
- LED indication of sensor power, switching and solenoid status
- 2-wire DC output sensor for process environments in hazardous areas
Request a quotation for the Series 54-HS Inductive Proximity Sensor
Send your sizes, connection type and duty conditions. We reply with price, lead time and documentation scope within one business day.