Клапаны, приводы и арматура управления Bray для промышленных заказчиков
Series 54-HS Inductive Proximity Sensor

Series 54-HS Inductive Proximity Sensor

The 54 series proximity sensor provides position indication for quarter-turn valves. Its superior design offers reliable, durable valve monitoring and control for efficient plant operation, mounting directly to VDI/VDE.

Series 54-HSмодель
Control Accessoriesгруппа
Brayбренд
Ключевые характеристики
Switching Function Intrinsic Safety - NAMUR = 2 x normally open (NC); DC 2-wire = 2 x normally open (NO)
Output Type Intrinsic Safety = NAMUR; DC 2-wire = 2 x normally open (NO)
Communication Protocols None
Rated Operating Distance Intrinsic Safety - NAMUR = 0 … 2.4mm; DC 2-wire = 0 … 2.05mm
Информация о заказе
Срок поставки7–15 дней
Минимальный заказ≥1

Технические характеристики

The 54 series proximity sensor provides position indication for quarter-turn valves. Its superior design offers reliable, durable valve monitoring and control for efficient plant operation, mounting directly to VDI/VDE 3845 compliant actuators for a smaller envelope and cost savings.

Features:

  • Two independent sensors indicate open and closed valve positions
  • Optimal design for high-pressure flush and corrosive flush applications
  • Tightly sealed against ingress of liquids and solids
  • Suited to dirty process environments and rapid cycling
  • Rugged design resists shock, vibration, UV and corrosion
  • Maintenance-free: contactless sensors eliminate mechanical wear and potential switch welding, arcing and sparking
  • Fast, simple installation
  • LED indication of sensor power, switching and solenoid status
  • 2-wire DC output sensor for process environments in hazardous areas

A DC 2-wire sensor for reliable operation in hazardous-area process environments — a compact proximity sensor for precise valve monitoring.

Switching Function Intrinsic Safety - NAMUR = 2 x normally open (NC); DC 2-wire = 2 x normally open (NO)
Output Type Intrinsic Safety = NAMUR; DC 2-wire = 2 x normally open (NO)
Communication Protocols None
Rated Operating Distance Intrinsic Safety - NAMUR = 0 … 2.4mm; DC 2-wire = 0 … 2.05mm
Enclosure Ratings Intrinsic Safety = IP67; DC 2-wire = IP66/67/69K
Connections Intrinsic Safety; qty 1: M12 x 1 pin connector; qty 1: M12 x 1 and qty 1: RD24x18 pin connectors; qty 2: M20 x 1.5 cable glands; DC 2-wire
Operating Voltage Intrinsic Safety 8V; DC 2-wire 6 - 30V
Mounting NAMUR/ VDI VDE 3845
Switching Frequency Intrinsic Safety = 0 ... 3 kHz; DC 2-wire = 0 ... 100 Hz
Temperature Range Intrinsic Safety = -25 ... 100°C (-13 ... 212°F); DC 2-wire = -40 ... 75°C (-40 ... 167°F
Certifications Intrinsic Safety - NAMUR; cULus Listed, General Purpose (E248934); DC 2-wire

Особенности и преимущества

  • Two independent sensors indicate open and closed valve positions
  • Optimal design for high-pressure flush and corrosive flush applications
  • Tightly sealed against ingress of liquids and solids
  • Suited to dirty process environments and rapid cycling
  • Rugged design resists shock, vibration, UV and corrosion
  • Maintenance-free: contactless sensors eliminate mechanical wear and potential switch welding, arcing and sparking
  • Fast, simple installation
  • LED indication of sensor power, switching and solenoid status
  • 2-wire DC output sensor for process environments in hazardous areas

Запросить КП на Series 54-HS Inductive Proximity Sensor

Укажите размеры, тип присоединения и условия работы. В течение одного рабочего дня ответим с ценой, сроком и составом документации.

Recently viewed

Нужно коммерческое предложение или техпаспорт?

Пришлите ваши параметры — ответим в течение одного рабочего дня.

Запросить предложение