Four symptoms of a failed steam trap

Live steam loss, cold equipment, waterhammer and cycling noise all point to different failure modes.

A failed steam trap is one of the most expensive items in a steam plant, because the loss is invisible until the fuel bill arrives.

1. Live steam at the discharge

A trap that blows live steam has failed open. On a thermodynamic trap this usually means a worn disc or a damaged seat.

2. Cold equipment downstream

Failed closed traps flood the equipment. Check strainer blockage before replacing the trap.

3. Waterhammer

Condensate backing up into the mains causes hammer and can damage fittings. Fix the trap, not the noise.